Sale!

140CPU31110

Original price was: $ 4,613.00.Current price is: $ 3,549.00.

Unity Processor Modicon Quantum – 548KB – 66MHz  140CPU31110

In stock

Description

Unity Processor Modicon Quantum – 548KB – 66MHz  140CPU31110

Main
range of product
Modicon Quantum automation platform
product or component type
Unity processor
Complementary
clock frequency
66 MHz
number of slots
16
6
2
4
10
number of racks
2 – local rack(s)
number of distributed I/O station
63 station(s) – 1 rack(s) – 3 Modbus Plus network(s)
number of remote I/O station
31 – 2 S908 remote I/O rack(s)
0 – 0 ethernet remote I/O rack(s)
discrete I/O number
8000 inputs, 8000 outputs – distributed – per network Modbus Plus
31744 inputs, 31744 outputs – remote
Unlimited (27 slots max) – local
analogue I/O number
Unlimited (27 slots max) – local
1984 inputs,1984 outputs – S908 remote I/O
500 inputs, 500 outputs – distributed – per network Modbus Plus
application specific I/O
Counter
Accurate time stamping
High-speed interrupt inputs
Serial link
number of optional modules
2 ( Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max)
maximum number of connections
1 ( USB)
2 ( AS-Interface) – distributed
2 ( Ethernet TCP/IP) – local
2 ( Modbus Plus) – local
2 ( Modbus) – RS232/485 Modbus/ASCII
2 ( Profibus DP) – local
4 ( AS-Interface) – remote
integrated connection type
1 Modbus Plus with
2 Modbus with
checks
Process control
memory description
Internal RAM 548 kB
switch function
Slide switch memory port/off
Slide switch communication port : ASCII/RTU/Memory
application structure
1 cyclic/periodic master task –
1 periodic fast task –
16 timer interrupt tasks –
64 I/O interrupt tasks –
64 interrupt tasks –
No auxiliary task –
execution time per instruction
0.1…0.27 µs floating points
0.1…0.27 µs on fixed-point arithmetic
0.12…0.585 µs Boolean
0.12…0.585 µs on word
number of instructions per ms
1.86 Kinst/ms if 100 % Boolean
2.49 Kinst/ms if 65 % Boolean and 35 % numerical
system overhead
1 ms – master task
0.2 ms – fast task
bus current requirement
1800 mA
local signalling
1 LED green communications are active on the Modbus Plus port (Modbus Plus)
1 LED green communications are active on the Modbus port (Modbus)
1 LED green CPU has been started and is solving logic (RUN)
1 LED green CPU has passed the power-up diagnostic tests (READY)
1 LED orange write-protected memory (memory port)
1 LED red battery needs replacing or is not present (BAT LOW)
1 LED red communications error on the Modbus Plus port (ERROR A)
electrical connection
1 female connector, connector type: SUB-D 9 for connecting to the Modbus Plus network
2 female connectors, connector type: SUB-D 9 for connecting to the Modbus bus
Environment
product certifications
CE
UL
CSA
standards
HazLoc
Ordering and shipping details
Category
18150 – QUANTUM CONTROLLERS,HSBY,COMM.
Discount Schedule
PC21
GTIN
00785901663386
Nbr. of units in pkg.
1
Package weight(Lbs)
1.7
Returnability
N
Country of origin
FR