Main
range of product Modicon STB distributed I/O solution
product or component type Standard analog input kit
kit composition STBART0200 module
STBXTS1100, 6-terminal screw type connector
STBXBA1000 base
STBXTS2100, 6-terminal spring clamp connector
analogue input type Voltage +/- 80 mV
Temperature probe -100…+260 °C Cu 10 2, 3 or 4 wires IEC
Temperature probe -100…+450 °C Pt 100 2, 3 or 4 wires US/JIS
Temperature probe -100…+450 °C Pt 1000 2, 3 or 4 wires US/JIS
Temperature probe -200…+850 °C Pt 100 2, 3 or 4 wires IEC
Temperature probe -200…+850 °C Pt 1000 2, 3 or 4 wires IEC
Temperature probe -60…+180 °C Ni 100 2, 3 or 4 wires IEC
Temperature probe -60…+180 °C Ni 1000 2, 3 or 4 wires IEC
Thermocouple +130…+1820 °C thermocouple B
Thermocouple -200…+760 °C thermocouple J
Thermocouple -270…+1000 °C thermocouple E
Thermocouple -270…+1370 °C thermocouple K
Thermocouple -270…+400 °C thermocouple T
Thermocouple -50…+1665 °C thermocouple R
Thermocouple -50…+1665 °C thermocouple S
analogue input number 2
analogue input resolution 15 bits + sign
type of filter Single low pass input filter 25 Hz
Complementary
absolute maximum input +/- 7.5 V DC
cold swapping Yes
hot swapping fallback Yes for standard NIMs
fallback status State 0 basic NIMs
User configurable standard NIMs
data format EN 61131-2
IEC 61131-2
input impedance 10 MOhm +/- 80 mV
maximum supply current for sensors 100 mA per input channels
protection type Short-circuit protection
absolute accuracy error +/- 0.1 % of full scale 25 °C internal
+/- 0.15 % of full scale 25 °C external
insulation between channels and logic bus 1500 V for 1 minute
addressing requirement 1 word for cold-junction compensation
2 input words
product compatibility Mounting base STBXBA1000
Power distribution module STBPDT3100/3105
[Us] rated supply voltage 24 V DC
supply Power distribution module
current consumption 30 mA at 5 V DC for logic bus
measurement resolution 0.01 mV voltage
0.1 °C or 0.1 °F temperature probe
0.1 °C or 0.1 °F thermocouple
conversion time 150 ms voltage 60 Hz
170 ms voltage 50 Hz
180 ms temperature probe 60 Hz 2 or 4 wires
200 ms temperature probe 50 Hz 2 or 4 wires
210 ms thermocouple with internal cold-junction compensation 60 Hz
230 ms thermocouple with internal cold-junction compensation 50 Hz
300 ms temperature probe 60 Hz 3 wires
340 ms temperature probe 50 Hz 3 wires
360 ms thermocouple with external cold-junction compensation 60 Hz
400 ms thermocouple with external cold-junction compensation 50 Hz
maximum wiring resistance 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires
20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires
20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires
200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires
200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires
50 Ohm Cu 10 IEC/US/JIS 4 wires
50 Ohm Ni 100 IEC/US/JIS 4 wires
50 Ohm Pt 100 IEC/US/JIS 4 wires
500 Ohm Ni 1000 IEC/US/JIS 4 wires
500 Ohm Pt 1000 IEC/US/JIS 4 wires
measurement accuracy +/- 1 °C Ni 100 25 °C external
+/- 1 °C Ni 100 25 °C internal
+/- 1 °C Ni 1000 25 °C external
+/- 1 °C Ni 1000 25 °C internal
+/- 1 °C Pt 100 25 °C internal
+/- 1 °C Pt 1000 25 °C internal
+/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C
+/- 2 °C Pt 100 25 °C external
+/- 2 °C Pt 1000 25 °C external
+/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C
+/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C
+/- 4 °C Cu 10 25 °C external
+/- 4 °C Cu 10 25 °C internal
+/- 4 °C thermocouple K with internal cold-junction compensation 25 °C
+/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C
+/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C
+/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C
+/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C
+/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C
+/- 5 °C thermocouple S with internal cold-junction compensation 60 °C
+/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C
+/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C
+/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C
+/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C
+/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C
+/- 7 °C thermocouple J with internal cold-junction compensation 60 °C
marking CE
overvoltage category II
status LED 1 LED (green) module status (RDY)
1 LED (red) module error (ERR)
Environment
product certifications UL
FM Class 1 Division 2
CSA
ATEX Cat 3G
C-Tick
pollution degree 2 conforming to IEC 60664-1
operating altitude <= 2000 m
IP degree of protection IP20 conforming to EN 61131-2 class 1
ambient air temperature for operation 0…70 °C
ambient air temperature for operation 32…140 °F without derating
ambient air temperature for storage -40…85 °C without derating
ambient air temperature for storage -40…185 °F without derating
relative humidity 95 % at 60 °C without condensation
vibration resistance +/-0.35 mm at 10…58 Hz
3 gn at 58…150 Hz on 35 x 7.5 mm symmetrical DIN rail
5 gn at 58…150 Hz on 35 x 15 mm symmetrical DIN rail
shock resistance 30 gn for 11 ms conforming to IEC 88 reference 2-27
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 136.0 g
Package 1 Height 2.5 cm
Package 1 width 8 cm
Package 1 Length 13 cm
Unit Type of Package 2 S02
Number of Units in Package 2 42
Package 2 Weight 6.1 kg
Package 2 Height 15 cm
Package 2 width 30 cm