Range of product | Sepam series 40 Sepam series 80 NPP Sepam series 60 Sepam series 80 |
---|---|
Device short name | ACE850TP |
communication port protocol | ARP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX FTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX HTTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX IEC 61850 network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX Modbus RTU network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX Modbus TCP/IP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX RSTP 801.1d 2004 network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX SNMP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX SNTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX |
---|---|
local signalling | Green LED1 for energized (front face) Green LED2 for communication status ok (front face) Green LED3 off for port 2 Ethernet 10 Mbit/s (front face) Green LED3 on for port 2 Ethernet 100 Mbit/s (front face) Green LED4 flashing for port 2 Ethernet sending data and receiving data (front face) Green LED5 off for port 1 Ethernet 10 Mbit/s (front face) Green LED5 on for port 1 Ethernet 100 Mbit/s (front face) Green LED6 flashing for port 1 Ethernet sending data and receiving data (front face) Red LED1 flashing for not set up or not base-unit connected (front face) Red LED1 off for de-energized (front face) Red LED1 remains ON for fault (front face) |
[Us] rated supply voltage | 110…240 V AC tolerance: – 20…10 % 24…250 V DC tolerance: – 20…10 % |
Mounting mode | Fixed |
Mounting support | Symmetrical DIN rail |
Height | 127 mm |
Width | 171 mm |
Depth | 58 mm |
Product weight | 0.4 kg |
mechanical robustness | Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3 Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3 Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2 Shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2 Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2 Vibrations de-energized (level: 2) : 2 Gn, 10 Hz…150 Hz conforming to IEC 60255-21-1 Vibrations in operation (level: 2) : 1 Gn, 10 Hz…150 Hz conforming to IEC 60255-21-1 Vibrations in operation (level: Fc) : 2 Hz…13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6 |
maximum cable distance between devices | <100 m |
auxiliary connection terminal | Functional earth: ring lug 1 pin(s) 1 cable(s) tinned copper braid 4 mm² Protective earth: screw-type connector 1 pin(s) 1 cable(s) wire 2.5 mm² <3 m Supply: screw-type connector 3 pin(s) 1 cable(s) wire 0.5…2.5 mm² Supply: screw-type connector 3 pin(s) 1 cable(s) wire 1.5 mm² Supply: screw-type connector 3 pin(s) 1 cable(s) wire 2.5 mm² Supply: screw-type connector 3 pin(s) 2 cable(s) wire 0.5…1 mm² Supply: screw-type connector 3 pin(s) 2 cable(s) wire 1 mm² Supply: screw-type connector 4 pin(s) 1 cable(s) wire 0.5…2.5 mm² Supply: screw-type connector 4 pin(s) 1 cable(s) wire 1.5 mm² Supply: screw-type connector 4 pin(s) 1 cable(s) wire 2.5 mm² Supply: screw-type connector 4 pin(s) 2 cable(s) wire 0.5…1 mm² Supply: screw-type connector 4 pin(s) 2 cable(s) wire 1 mm² |
wire stripping length | Supply: 8 mm |
electromagnetic compatibility | 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12 Conducted disturbance emission: (emission tests), conforming to IEC 60255-25 Conducted disturbance emission: (emission tests), B, conforming to EN 55022 Disturbing field emission: (emission tests), conforming to IEC 60255-25 Disturbing field emission: (emission tests), A, conforming to EN 55022 Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3 Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2 Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1 Fast transient bursts: (immunity tests-conducted disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4 Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4 Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6 Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8 Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz…1 GHz, conforming to IEC 60255-22-3 Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz…1 GHz, conforming to ANSI C37.90.2 (1995) Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz…2 GHz, conforming to IEC 61000-4-3 Surges: (immunity tests-conducted disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5 Voltage interruptions: (immunity tests-conducted disturbances), 100 %, 10 ms, conforming to IEC 60255-11 |
---|---|
climatic withstand | Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60 Continuous exposure to damp heat (in operation) : Ca: 10 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3 Continuous exposure to damp heat (in storage) : Ca: 56 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3 Exposure to cold (in operation) : Ab: – 25 °C (- 13 °F) conforming to IEC 60068-2-1 Exposure to cold (in storage) : Ab: – 25 °C (- 13 °F) conforming to IEC 60068-2-1 Exposure to dry heat (in operation) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2 Exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2 Influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60 Salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52 Temperature variation with specified variation rate (in operation) : Nb: – 25 °C to 70 °C (- 13 °F to 158 °F) 5 °C/min (41 °F/min) conforming to IEC 60068-2-14 |
Ambient air temperature for operation | -25…70 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 9.800 cm |
Package 1 Width | 16.700 cm |
Package 1 Length | 19.800 cm |
Package 1 Weight | 721 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 6 |
Package 2 Height | 30.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 4.733 kg |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 48 |
Package 3 Height | 44.500 cm |
Package 3 Width | 80.000 cm |
Package 3 Length | 120.000 cm |
Package 3 Weight | 49.784 kg |