Description
Range of product | Altistart 48 |
---|---|
Product or component type | Soft starter |
Product destination | Asynchronous motors |
Product specific application | Heavy duty industry and pumps |
device short name | ATS48 |
Utilisation category | AC-53A |
Ue power supply voltage | 208…690 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % |
Motor power kW | 110 kW at 400 V for standard applications 110 kW at 440 V for standard applications 110 kW at 500 V for severe applications 110 kW at 525 V for severe applications 132 kW at 500 V for standard applications 132 kW at 525 V for standard applications 132 kW at 660 V for severe applications 160 kW at 660 V for standard applications 160 kW at 690 V for severe applications 200 kW at 690 V for standard applications 45 kW at 230 V for severe applications 55 kW at 230 V for standard applications 90 kW at 400 V for severe applications 90 kW at 440 V for severe applications |
Motor power hp | 125 hp at 460 V for severe applications 150 hp at 460 V for standard applications 150 hp at 575 V for severe applications 200 hp at 575 V for standard applications 50 hp at 208 V for severe applications 60 hp at 208 V for standard applications 60 hp at 230 V for severe applications 75 hp at 230 V for standard applications |
device connection | In the motor supply line |
---|---|
Protection type | Phase failure: line Thermal protection: motor Thermal protection: starter |
Standards | EN/IEC 60947-4-2 |
product certifications | DNV GOST SEPRO TCF UL CCC NOM 117 C-Tick CSA |
Marking | CE |
Discrete input number | 5 |
Discrete input type | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
Discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
Minimum switching current | 10 mA at 6 V DC for relay outputs |
Discrete output number | 2 |
Discrete output type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
Analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
communication port protocol | Modbus |
connector type | 1 RJ45 |
Communication data link | Serial |
Physical interface | RS485 multidrop |
Transmission rate | 4800, 9600 or 19200 bps |
function available | External bypass (optional) |
Operating position | Vertical +/- 10 degree |
Height | 380 mm |
Width | 320 mm |
Depth | 265 mm |
Net weight | 18.2 kg |
Electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
---|---|
Relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
Ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
Ambient air temperature for storage | -25…70 °C |
Operating altitude | <= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 43.000 cm |
Package 1 Width | 46.000 cm |
Package 1 Length | 51.000 cm |
Package 1 Weight | 23.000 kg |